CMS3300
Features
CMS3300 is a completely automatic Electrolyte Analyzer, whose applicable electrolyte includes K Na Cl Ca Li PH CO2 and Anion Gap (AG). It implements advanced ion- measurement technology to directly measure the concentration of K Na Cl Ca PH Li TCO2 and AG in blood serum, blood plasma, whole blood, and cerebrospinal fluid and dilute urine. It's a kind of clinical inspection equipment which is quick, accurate, convenient and practical. n The whole running process of the equipment is controlled by a computer .Also , automatic electric potential tracking and correcting software are adopted to ensure its stable performance. n The machine adopts innovative international patent technology such as wave theory flushing method and direct flushing pipe method to avoid block and n Every time putting the specimen into the machine,the machine could simultaneously detect eight ions including K, Na, Cl, iCa, Nca,TCa, pH, Li,TCO2, AG as well as ten parameters. n It can absorb the specimen and calibrate the ion automatically , and make analysis quickly. It only takes 25s to finish the process of absorbing the specimen to n After conducting analysis to specimens, the equipment will automatically flush , keeping the electrode standby in clean status. n It has a ult5a large screen with completely Chinese display ,which is quite clear for operators.The built-in printer can print out the result ,so it's very quick and n The equipment is set with quality control correction procedure, and capable n The equipment is capable of storing 1000 result, and it can be extended to be n The equipment features power failure protection function.It can still store n The equipment can work 24 hours a day . If there is no operation for a long time , the equipment will change into standby state, making it accessible at any time . n The equipment can be powered off at any time and greatly save reagent.It is also suitable for private hospital and hospital of county and town level since Specifications: n Range and accuracy of measurement
crossed contamination.
indicatingthe result.
convenient.
of correcting measured date automatically,as well as by the two parameters
of pitch and average deviation.
more than 10000. The equipment will automatically refresh once it reaches the
store limit .
qualitycontrol and specimen data upon power failure.The storing time
exceeds 5years.
It is quite suitable for large/middle size hospitals of many emergency calls
and specimens.
two hospitalsare of less specimen quantities.
n Applicable specimens:blood serum,blood p;asma,whole blood,cerebrospinal fluid and
dilute urine
n Quantity of specimens:60~300ul(item3 to item 10)
n Ambient temperature:5~35℃
n Velocity for measurement:≤25S
n Requirement on power supply:220V±10V 50Hz60Hz
n Power rate:400W